Ateis IDA8C User Manual Page 73

  • Download
  • Add to my manuals
  • Print
  • Page
    / 446
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 72
Product Features 73
© 2012 ATEÏS
1. Update firmware using newest version of Ateis Studio.
2. Store configuration. It the problem still not solved, please contact service.
4.1.6.1.6 No Preset Error
Fault Meaning
There is no configuration inside device.
Fault Indication
LED Indicator
When this error is detected, following LEDs will light up:
o System Fault LED on front panel of IDA8C/S.
o G. Fault LED on front panel of IDA8C/S.
Log
Text messages display at touch screen on front panel of IDA8C:
"No Preset Table"
Text message display at window [Machine Fault Record] of Ateis Studio:
Buzzer sound output to monitoring speaker on front panel of IDA8C.
Fault Handling
Store a configuration to device. If the error still not solved please contact service.
4.1.6.1.7 SPI Flash Error
Fault Meaning
An internal error of micro controller SPI communication.
Fault Indication
LED Indicator
When this error is detected, following LEDs will light up:
o System Fault LED on front panel of IDA8C/S.
o G. Fault LED on front panel of IDA8C/S.
Log
Text messages display at touch screen on front panel of IDA8C:
"SPI Flash Error"
Page view 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 445 446