Measurement
After parameter settings are done in lower part grid, IDA8C/S start to measure value get from internal
circuit, and display it on the grid at upper part of window:
There are fields of the grid:
Leakage Impedance
The impedance between LineA/B +/- signal and ground cause current to leak.
Reference A (ohm)
Show the impedance value for reference get from Line A output.
Reference B (ohm)
Show the impedance value for reference get from Line B output.
Reference A&B (ohm)
Show the impedance value for reference get from Line A & B.
Current Amp
Show the amplifier for the zone is normal amplifier or backup amplifier.
Measure (ohm)
Show the impedance value of Line A & B.
Diff(%)
Show the difference percentage of Measure(ohm) and Reference A&B(ohm)
Faults