amplifier.
Contact Outputs
8 logic outputs channels to close/open circuit for an external device, this contact is normally open.
Evacuation Inputs
9 evacuation contact inputs that allow the monitoring of external contact. They also can be used in
UGA mode, trigger by a voltage polarization change.
24V DC Output
This connector supplies a 24VDC source.
24V DC Input
Main 24VDC power supply connector.
AC Power Socket
Main 110~240 V 1.2A, 47~63Hz AC power input with fuse. If 24V DC and AC power input at the
same time, IDA8C will use AC power, and switch to DC power if there is no AC power input.
Fuse Rating: 1.6A
4.1.3.4 Characteristics
Case
Dimension = 436mm (W) x 300mm (L) x 88mm (H).
Weight = 5Kg.
Color = RAL7016.
Power
AC Maximum Consumption = 45 W.
Amplifier Zone Outputs
Maximum level = 14 dB
Output Impedance = 50 Ohm
THD+N(Total Harmonic Distortion plus Noise)
Sensitivity
Minimum
Maximum
Unit
Frequency
0dBu
-
0.04
%
20~20kHz@+4dBu
-12dBu
-
0.06
%
20~20kHz@-2dBu
-24dBu
-
0.06
%
20~20kHz@-14dBu
-40dBu
-
0.06
%
20~20kHz@-30dBu
-54dBu
-
0.06
%
20~20kHz@-44dBu