Type
Maximum
5ms
5 µs
50ms
20 µs
100ms
20 µs
200ms
20 µs
500ms
20 µs
1000ms
20 µs
2000ms
20 µs
*3: Maximum value of Distance is depend on the type of Delay (Advanced)
Type
Maximum
5ms
1.62 m
50ms
16.25 m
100ms
32.5 m
200ms
65 m
500ms
162.5 m
1000ms
325 m
2000ms
650 m
Element Description
Type
Choose between adjustments with Time or with Distance and temperature
Mute all
Mute all channel, the output of channel is mute if the value of this element or Mute is on.
Bypass all
Bypass audio signal of all channel, i.e. disable the delay function.
Mute
Mute the channel. the output of channel is mute if the value of this element or Mute all is on.
Bypass
Bypass audio signal of the channel.
Delay time
Specify how much time will be delayed for the audio signal of channel.
Temp
Specify the temperate to compute the delay time for channel.
Distance
Specify the Distance to compute the delay time for channel.
Note: If a channel is mute and bypass at the same time, the audio signal of the channel will mute.
Application
Imagine a conference in a large room. Normally speakers are beside the people speaking, so
listeners at the end of the room receive too weak sound. Solution is to put also speakers in the